Gohn For example, the presence of Pseudomonas sp. For example, the leakage of chamber shelf fluid into the chamber or a break in sterility would be oc for rejection of the batch. As with immediate release potency testing, stability testing should be performed on vials with a known9 von 17 There are three types of pumps, rotary vane, rotary piston and mechanical booster. As with many decisions made by manufacturers, there is a level of risk associated with the operation, process or system, which only the manufacturer can decide. As lyophilizatlon any ethylene oxide treatment, humidification is necessary.

Author:Sajin Doular
Country:Malta
Language:English (Spanish)
Genre:Life
Published (Last):18 April 2016
Pages:496
PDF File Size:18.6 Mb
ePub File Size:3.68 Mb
ISBN:282-6-92390-898-4
Downloads:5431
Price:Free* [*Free Regsitration Required]
Uploader:Meztilabar



The document does not bind FDA, and does no confer any rights, privileges, benefits, or immunities for or on any person s. INTRODUCTION Lyophilization or freeze drying is a process in which water is removed from a product after it is frozen and placed under a vacuum, allowing the ice to change directly from solid to vapor without passing through a liquid phase. The process consists of three separate, unique, and interdependent processes; freezing, primary drying sublimation , and secondary drying desorption.

The advantages of lyophilization include: Ease of processing a liquid, which simplifies aseptic handling Enhanced stability of a dry powder Removal of water without excessive heating of the product Enhanced product stability in a dry state Rapid and easy dissolution of reconstituted product Disadvantages of lyophilization include: Increased handling and processing time Need for sterile diluent upon reconstitution Cost and complexity of equipment The lyophilization process generally includes the following steps: Dissolving the drug and excipients in a suitable solvent, generally water for injection WFI.

Sterilizing the bulk solution by passing it through a 0. Filling into individual sterile containers and partially stoppering the containers under aseptic conditions. Transporting the partially stoppered containers to the lyophilizer and loading into the chamber under aseptic conditions. Freezing the solution by placing the partially stoppered containers on cooled shelves in a freeze-drying chamber or pre-freezing in another chamber.

Applying a vacuum to the chamber and heating the shelves in order to evaporate the water from the frozen state. Complete stoppering of the vials usually by hydraulic or screw rod stoppering mechanisms installed in the lyophilizers. There are many new parenteral products, including anti-infectives, biotechnology derived products, and in-vitro diagnostics which are manufactured as lyophilized products. Additionally, inspections have disclosed potency, sterility and stability problems associated with the manufacture and control of lyophilized products.

In order to provide guidance and information to investigators, some industry procedures and deficiencies associated with lyophilized products are identified in this Inspection Guide. It is recognized that there is complex technology associated with the manufacture and control of a lyophilized pharmaceutical dosage form. Some of the important aspects of these operations include: the formulation of solutions; filling of vials and validation of the filling operation; sterilization and engineering aspects of the lyophilizer; scale-up and validation of the lyophilization cycle; and testing of the end product.

This discussion will address some of the problems associated with the manufacture and control of a lyophilized dosage form. Many of the antibiotics, such as some of the semi-synthetic penicillins, cephalosporins, and also some of the salts of erythromycin, doxycycline and chloramphenicol are made by the lyophilization process.

Because they are antibiotics, low bioburden of these formulations would be expected at the time of batching. However, some of the other dosage forms that are lyophilized, such as hydrocortisone sodium succinate, methylprednisolone sodium succinate and many of the biotechnology derived products, have no antibacterial effect when in solution.

For these types of products, bioburden should be minimal and the bioburden should be determined prior to sterilization of these bulk solutions prior to filling. Obviously, the batching or compounding of these bulk solutions should be controlled in order to prevent any potential increase in microbiological levels that may occur up to the time that the bulk solutions are filtered sterilized. The concern with any microbiological level is the possible increase in endotoxins that may develop.

Good practice for the compounding of lyophilized products would also include batching in a controlled environment and in sealed tanks, particularly if the solution is to be held for any length of time prior to sterilization.

In some cases, manufacturers have performed bioburden testing on bulk solutions after prefiltration and prior to final filtration. While the testing of such solutions may be meaningful in determining the bioburden for sterilization, it does not provide any information regarding the potential formation or presence of endotoxins. While the testing of 0. For example, the presence of Pseudomonas sp. The stopper is placed on top of the vial and is ultimately seated in the lyophilizer. As a result the contents of the vial are subject to contamination until they are actually sealed.

Validation of filling operations should include media fills and the sampling of critical surfaces and air during active filling dynamic conditions. Because of the active involvement of people in filling and aseptic manipulations, an environmental program should also include an evaluation of microbiological levels on people working in aseptic processing areas.

Manufacturers are actively sampling the surfaces of personnel working in aseptic processing areas. It states under the heading of "Interpretation of Quality Control Tests" that review consideration should be paid to environmental control data, including In those situations in which manufacturers have failed to perform some type of personnel monitoring, or monitoring has shown unacceptable levels of contamination, regulatory situations have resulted.

Typically, vials to be lyophilized are partially stoppered by machine. However, some filling lines have been noted which utilize an operator to place each stopper on top of the vial by hand. At this time, it would seem that it would be difficult for a manufacturer to justify a hand-stoppering operation, even if sterile forceps are employed, in any type of operation other than filling a clinical batch or very small number of units.

Significant regulatory situations have resulted when some manufacturers have hand-stoppered vials. Again, the concern is the immediate avenue of contamination offered by the operator.

It is well recognized that people are the major source of contamination in an aseptic processing filling operation. The longer a person works in an aseptic operation, the more microorganisms will be shed and the greater the probability of contamination. Once filled and partially stoppered, vials are transported and loaded into the lyophilizer. The transfer and handling, such as loading of the lyophilizer, should take place under primary barriers, such as the laminar flow hoods under which the vials were filled.

Validation of this handling should also include the use media fills. Regarding the filling of sterile media, there are some manufacturers who carry out a partial lyophilization cycle and freeze the media. While this could seem to greater mimic the process, the freezing of media could reduce microbial levels of some contaminants. Since the purpose of the media fill is to evaluate and justify the aseptic capabilities of the process, the people and the system, the possible reduction of microbiological levels after aseptic manipulation by freezing would not be warranted.

The purpose of a media fill is not to determine the lethality of freezing and its effect on any microbial contaminants that might be present. In an effort to identify the particular sections of filling and aseptic manipulation that might introduce contamination, several manufacturers have resorted to expanded media fills. That is, they have filled approximately vials during a media fill and segmented the fill into three stages.

One stage has included filling of vials and stoppering on line; another stage included filling vials, transportation to the lyophilizer and then stoppering; a third stage included the filling of vials, loading in the lyophilizer, and exposure to a portion of the nitrogen flush and then stoppering. Since lyophilizer sterilization and sterilization of the nitrogen system used to backfill require separate validation, media fills should primarily validate the filling, transportation and loading aseptic operations.

The question of the number of units needed for media fills when the capacity of the process is less than units is frequently asked, particularly for clinical products. Again, the purpose of the media fill is to assure that product can be aseptically processed without contamination under operating conditions. It would seem, therefore, that the maximum number of units of media filled be equivalent to the maximum batch size if it is less than units.

After filling, dosage units are transported to the lyophilizer by metal trays. Usually, the bottom of the trays are removed after the dosage units are loaded into the lyophilizer. Thus, the dosage units lie directly on the lyophilizer shelf. There have been some situations in which manufacturers have loaded the dosage units on metal trays which were not removed. Unfortunately, at one manufacturer, the trays warped which caused a moisture problem in some dosage units in a batch. In the transport of vials to the lyophilizer, since they are not sealed, there is concern for the potential for contamination.

During inspections and in the review of new facilities, the failure to provide laminar flow coverage or a primary barrier for the transport and loading areas of a lyophilizer has been regarded as an objectionable condition.

One manufacturer as a means of correction developed a laminar flow cart to transport the vials from the filling line to the lyophilizer. Other manufacturers building new facilities have located the filling line close to the lyophilizer and have provided a primary barrier extending from the filling line to the lyophilizer. In order to correct this type of problem, another manufacturer installed a vertical laminar flow hood between the filling line and lyophilizer. Initially, high velocities with inadequate return caused a contamination problem in a media fill.

It was speculated that new air currents resulted in rebound contamination off the floor. Fortunately, media fills and smoke studies provided enough meaningful information that the problem could be corrected prior to the manufacture of product. Typically, the lyophilization process includes the stoppering of vials in the chamber. Another major concern with the filling operation is assurance of fill volumes.

Obviously, a low fill would represent a subpotency in the vial. Unlike a powder or liquid fill, a low fill would not be readily apparent after lyophilization particularly for a biopharmaceutical drug product where the active ingredient may be only a milligram.

Because of the clinical significance, sub-potency in a vial potentially can be a very serious situation. For example, in the inspection of a lyophilization filling operation, it was noted that the firm was having a filling problem.

The gate on the filling line was not coordinated with the filling syringes, and splashing and partial filling was occurring. It was also observed that some of the partially filled vials were loaded into the lyophilizer. This resulted in rejection of the batch. On occasion, it has been seen that production operators monitoring fill volumes record these fill volumes only after adjustments are made.

Therefore, good practice and a good quality assurance program would include the frequent monitoring of the volume of fill, such as every 15 minutes. Good practice would also include provisions for the isolation of particular sections of filling operations when low or high fills are encountered. There are some atypical filling operations which have not been discussed.

For example, there have also been some situations in which lyophilization is performed on trays of solution rather than in vials. Based on the current technology available, it would seem that for a sterile product, it would be difficult to justify this procedure. The dual chamber vial also presents additional requirements for aseptic manipulations. Media fills should include the filling of media in both chambers. Also, the diluent in these vials should contain a preservative. Without a preservative, the filling of diluent would be analogous to the filling of media.

In some cycles, the shelves are at the temperature needed for freezing, while for other cycles, the product is loaded and then the shelves are taken to the freezing temperature necessary for product freeze. In those cycles in which the shelves are precooled prior to loading, there is concern for any ice formation on shelves prior to loading.

Ice on shelves prior to loading can cause partial or complete stoppering of vials prior to lyophilization of the product. A recent field complaint of a product in solution and not lyophilized was attributed to preliminary stoppering of a few vials prior to exposure to the lyophilization cycle.

Typically, the product is frozen at a temperature well below the eutectic point. The scale-up and change of lyophilization cycles, including the freezing procedures, have presented some problems. Studies have shown the rate and manner of freezing may affect the quality of the lyophilized product. For example, slow freezing leads to the formation of larger ice crystals. This results in relatively large voids, which aid in the escape of water vapor during sublimation.

On the other hand, slow freezing can increase concentration shifts of components. Also, the rate and manner of freezing has been shown to have an affect on the physical form polymorph of the drug substance. It is desirable after freezing and during primary drying to hold the drying temperature in the product at least o below the eutectic point.

COURS FRIGORISTE PDF

anabolicsteroids.me

Mauzilkree For example, in the determination of potency, it is sometimes common to reconstitute and assay the entire contents of a vial without knowing the weight of the sample. When working with products with low collapse temperatures, it may be necessary to wrap or insulate the flask to slow down the rate of heat transfer and avoid collapse. It is recommended that these records be reviewed early in the inspection. This can be accomplished manually using product thermocouples or, o drying in vials, an automated SMART system can be used. The refrigeration system must be able to maintain the temperature of the condenser substantially below the temperature of the product. Product chambers are typically either a manifold with attached flasks, or, a larger chamber with a system of shelves on which to place the product.

APPLIED DIGITAL CONTROL BY J.R.LEIGH PDF

U.S. Food and Drug Administration

Meztisar Annealing has the added advantage of larger crystal growth and corresponding shorter drying times. One could also think of it as low side, intermediate, and high side. The type and shape of product being dried and its end-use also need to be considered. The product temperature is monitored using thermocouples and then the shelf temperature set point is slowly increased until the product reaches its parenferals temperature. These products can benefit from a thermal treatment process, which is also called annealing.

CARTE DE BUCATE RETETE VEGETARIENE PDF

Guide to inspections of lyophilization of parenterals.

.

ABDULLAH MARTAL PDF

GUIDE TO INSPECTIONS OF LYOPHILIZATION OF PARENTERALS PDF

.

Related Articles